Fluke Temp Calibrators 3 models covering –25 °C to 660 °C,

FLUKE-914X Temperature calibrators with 3 models covering –25 °C to 660 °C. Built-in two-channel readout for PRT, RTD, thermocouple,4-20 mA current. The 9142 and 9143 have a display accuracy of ± 0.2 °C over their full range, and the 9144 display accuracy ranges from ± 0.35 °C at 420 °C to ± 0.5 °C at ± 660 °C
SKU: FLUKE-9142, FLUKE-9143, FLUKE-9144
Manufacturer: Fluke
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Call for pricing

FLUKE 9144X  - Temperature calibrators  with 3 models covering –25 °C to 660 °C.

Applications

Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Field Metrology Well is the right tool for the job. With three models covering the range of –25 °C to 660 °C, this family of Metrology Wells calibrates a wide range of sensor types. The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter. Each process version accepts an ITS-90 reference PRT. The built-in readout accuracy ranges from ± 0.01 °C to ± 0.07 °C depending on the measured temperature. Reference PRTs for Field Metrology Wells contain individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably. The second channel is user-selectable for 2-, 3-, or 4- wire RTDs, thermocouples, or 4-20 mA transmitters. For comparison calibration, don’t hassle with carrying multiple instruments to the field. Field Metrology Wells do it all as a single instrument.

 

Features

-  Lightweight, portable, and fast
-  Cool to –25 °C in 15 minutes and heat to 660 °C in 15 minutes
-  Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
-  True reference thermometry with accuracy to ± 0.01 °C
-  On-board automation and documentation
-  Metrology performance in accuracy, stability, uniformity, and loading

 

FLUKE 9144X  - Temperature calibrators  with 3 models covering –25 °C to 660 °C.

Applications

Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Field Metrology Well is the right tool for the job. With three models covering the range of –25 °C to 660 °C, this family of Metrology Wells calibrates a wide range of sensor types. The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter. Each process version accepts an ITS-90 reference PRT. The built-in readout accuracy ranges from ± 0.01 °C to ± 0.07 °C depending on the measured temperature. Reference PRTs for Field Metrology Wells contain individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably. The second channel is user-selectable for 2-, 3-, or 4- wire RTDs, thermocouples, or 4-20 mA transmitters. For comparison calibration, don’t hassle with carrying multiple instruments to the field. Field Metrology Wells do it all as a single instrument.

 

Features

-  Lightweight, portable, and fast
-  Cool to –25 °C in 15 minutes and heat to 660 °C in 15 minutes
-  Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
-  True reference thermometry with accuracy to ± 0.01 °C
-  On-board automation and documentation
-  Metrology performance in accuracy, stability, uniformity, and loading